薛文山 韩晓辉 张丽君 钟文保 史军致
摘要 通过对山西铝厂二期赤泥和粉煤灰堆场使用前后6年来地下水的监测数据进行显著性检验(F-检验和t-检验),统计分析和预测结果表明,该堆场在国内首次采取的防渗工程措施是良好的,堆场对该区域地下水水质未产生污染作用.
关键词 堆场,防渗工程,地下水质.Inwestingation on the anti-leakage project of disposal site of red mud and fly ash in shanxi aluminium plant and its influence on groundwaterXUE Wenshan,HAN Xiaohui,ZHANG Lijun,ZHONG Wenbao,SHI Junzhi(Environmental Monitoring Station,Yuncheng,Shanxi 044000)Abstract The six years monitoring data of the groundwater under the disposae site have been tested (used F-test and T-test) strictingly and statistically analysed.The results show that anti-leakage project is successful and the quality of the groundwater has not been polluted.Keywords disposal site,quality of groundwater,anti-leakage project